| Drug | Vd (L/kg) | k10 (/min) | ke0 (/min) |
|---|
The patient, the monitor and every clock are frozen. Take your time: check a dose, read a drug card, look something up. You can close this and still use the controls - anything you do takes effect when you resume.
Directed influence map. Green = positive drive, red = negative. Edge thickness reflects how active each pathway is right now; dashed edges are baroreflex feedback.
Synapse is source-available under the PolyForm Shield License 1.0.0. You may use, study, modify and share it for any purpose, except to provide a product that competes with Synapse.
Teaching with Synapse is welcome, in your own classes, courses and institution, free or paid. Republishing Synapse, or a modified version of it, as a simulator of your own is not. The premium scenarios are also covered by the Terms of use. The Hypnos Medical name and logo are not licensed.
Required Notice: Copyright 2025–2026 Hypnos Medical Limited. Provided "as is", without warranty of any kind. Versions before v4.68 were released under Apache-2.0.
Anaesthetists, trainee anaesthetists, simulation educators, and qualified clinicians using the simulator for self-directed study, teaching, or peer discussion of perioperative physiology and pharmacology.
For questions, feedback, or bug reports, please contact the author.
For the next while, you are the anaesthetist looking after a patient through an operation.
This screen is the patient monitor — the same kind that sits beside an anaesthetised patient in theatre. Your job is to keep them asleep, breathing, and stable while the surgery happens. The controls let you give drugs and respond to what the monitor is telling you.
This is a safe place to try things, make mistakes, and watch what happens — none of it can hurt anyone! Note that although the physiology is reasonably high-fidelity it does not capture every nuance, and real patients may behave differently.
The next three steps cover the monitor, the controls, and how to start your first case. You can reopen this any time from Start here in the top bar.
This is what you will be watching. You already know the basics like heart rate and blood pressure — the parts worth learning are the ones specific to anaesthesia. Here is what each part means.
Illustrative values for a stable, anaesthetised patient.
Everything you do happens through the three columns of controls below the monitor.
Anaesthetic is the drug deck, organised into tabs: hypnotics (to send the patient to sleep), opioids (pain relief), pressors (to raise blood pressure), other cardiovascular drugs, muscle relaxants (NMB), fluids, and emergency drugs. Tap a dose to give a bolus. Some drugs can also run as continuous infusions — switch to the Infusions tab and adjust the rate with a slider.
Not sure what a drug does? Tap its name (not a dose) for a card on how it works, what it does and what to watch for; on a computer, hovering over the name gives a one-line summary. The coloured chip beside each name is its syringe-label colour, as in theatre: yellow induction agents, blue opioids, red muscle relaxants, violet vasopressors, green anticholinergics. The Drug guide lists them all, and is always one tap away above the drug tabs.
Ventilator sets the airway device (mask, LMA or tube), the ventilation mode, and the settings: oxygen (FiO2), rate, tidal volume or inspiratory pressure, PEEP, sevoflurane and fresh gas flow. In Manual mode the machine does not breathe for the patient: they breathe for themselves, or you breathe for them with the bag.
Interventions are the things you do with your hands: suction the airway, squeeze the bag (Manual mode only), start CPR, tip the patient head down with the legs up, ask the surgeon to pause, and use the defibrillator — choose the energy, turn on SYNC for a synchronised cardioversion, charge, then shock. The HemoCue measures the haemoglobin from a drop of blood, the Coag screen gives the INR, fibrinogen and platelet count, the ROTEM shows how the clot forms, and the Blood gas gives the pH, oxygen, carbon dioxide, base excess and lactate. Every case starts with one 18G cannula, and fluids and blood run in through it at its own pace (a litre of crystalloid in about ten minutes, blood slower); + 16G IV line puts in a second, bigger one. Each bag shows in the header as it runs: click it twice to take it down.
Time runs at its real pace, and some changes take many minutes — a fluid bolus spreading into the tissues, the lactate of a shocked patient climbing, the clotting of a bleeding patient running down. The clock in the top bar shows how long the case has been running, and the button beside it lets you speed time up to 2×, 5× or 10× while you watch something develop; the waveforms keep their real speed. Speed drops back to 1× by itself when a new red alarm appears (untick Back to 1x on monitor alarms in the same menu to keep it running), and stays at 1× through a cardiac arrest, while you squeeze the bag and while the defibrillator is in use. Pause stops everything while you think.
The best place to begin is a guided scenario rather than a blank patient.
Tap Scenarios in the top bar and choose Induction and maintenance. It takes you step by step through sending a patient to sleep — the sequence every anaesthetic begins with. Every scenario comes with a brief setting out its setup, objectives, and hints.
When you are ready, press Get started below to jump straight to the scenario picker.
Pick a scenario to start. Sim continues running underneath; loading a scenario applies its setup.
| Drug | Vd (L/kg) | k10 (/min) | ke0 (/min) |
|---|
Learning objectives